Parameter Table for ROHS Testing Instruments

Parameter Description
Instrument Name XRF Spectrometer, ICP-OES, GC-MS, UV-Vis Spectrophotometer, AAS
Detected Substances Pb, Cd, Hg, Cr(VI), PBBs, PBDEs, phthalates (DIBP, DBP, BBP, DEHP)
Detection Range 0.1–1000 ppm (varies by substance and instrument)
Detection Limit As low as 0.1 ppm for metals (e.g., Cd), 1 ppm for organic compounds
Technology Used X-ray fluorescence (XRF), Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES), Gas Chromatography-Mass Spectrometry (GC-MS), Ultraviolet-Visible Spectroscopy (UV-Vis), Atomic Absorption Spectroscopy (AAS)
Application Scenarios Electronics, automotive, plastics, packaging, textiles, and industrial raw materials
Compliance Standards EU RoHS 2.0 (Directive 2011/65/EU), IEC 62321, China RoHS
Data Output Format CSV, PDF, or integrated QA/QC reports with pass/fail indicators
Calibration Cycle 6–12 months (traceable to ISO/IEC 17025 standards)

 

ROHS Testing Instruments are specialized analytical devices designed to detect and quantify restricted hazardous substances in electronic and electrical products, ensuring compliance with global regulations like EU RoHS 2.0.Key instruments include XRF spectrometers for rapid screening of metals (e.g., Pb, Cd), ICP-OES for high-precision metal analysis, and GC-MS for identifying organic pollutants such as phthalates and brominated flame retardants.